Performance Evaluation of Kaduna Refining and Petrochemical Company Boiler Furnace using Exergy Analysis
Article PDF

Keywords

Performance Evaluation; Refining; Petrochemical; Boiler furnace; Exergy Analysis; Flue gases.

How to Cite

Oko, O. (2024). Performance Evaluation of Kaduna Refining and Petrochemical Company Boiler Furnace using Exergy Analysis. Engineering Research Journal, 4(6), 33-55. https://www.openjournals.ijaar.org/index.php/erj/article/view/1439

Abstract

This study investigated the causes of operational inefficiencies and losses resulting in the decline of the expected output of the KRPC steam boiler furnace 1. The Exergy analysis was used to investigate the causes and locations of irresistibility and losses in the steam boiler furnace 1 which was experiencing frequent failures leading to the decline of expected output of the boiler facility. The data for the analysis were both base parameters and measured values kept in the control room operational log book for one year and inputted in the Aspen Hysys 8.4 software. The furnace operating parameters collected were, temperature, pressure, and mass flow rate from the input and output streams. The input streams were preheated water, air, and fuel, while the output streams were steam and flue gases. The identified values of the parameters temperature, pressure, and mass flow rate, and their streams were inputted into the Aspen Hysys model for simulation. The Aspen Hysys spreadsheet was used to compute the effects of; flue gasses temperature on exergy destruction and exergy efficiency, fuel oil pressure on exergy destruction and exergy efficiency, fuel oil sulfur content on exergy destruction and exergy efficiency, nitrogen content on, exergy destruction and exergy efficiency and the oxygen content on exergy destruction and exergy efficiency respectively. These processes showed high exergy destruction, of 445.4 kJ/kg in the boiler finance 1 which could be due to age, inadequate maintenance, or refractory breakdown. Other results showed that the energy and exergy efficiencies were 71.54% and 6.396% respectively. Physically, this discrepancy implies that although 71.54% of the input energy is transferred to the generated steam, the energy is degraded as it is transferred. The results of this study are one of the reasons for the poor performance of the KRPC PPU. It serves as a guide for formulation of maintenance policy of KRPC which can help to improve the equipment performance.

Article PDF
Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Copyright (c) 2025 Engineering Research journal

483 177