Evaluation of Drinking Water Quality Using Electrical Conductivity: A Case Study of Nassarawa Local Government Area, Kano State
Article PDF

Keywords

pH, Temperature, Mean Electrical conductivity, Standard Deviation

How to Cite

Abdullahi, A. H., Idris, S. S., Muhammad, M. D., & Muhammad, S. A. (2025). Evaluation of Drinking Water Quality Using Electrical Conductivity: A Case Study of Nassarawa Local Government Area, Kano State. Engineering Research Journal, 5(4), 129-139. https://doi.org/10.5281/zenodo.18180054

Abstract

This research was aimed at determining the electrical conductivity through different water samples, in Nassarawa Local Government Area of Kano. It assesses the quality of different drinking water samples by determining their electrical conductivities. Samples of Borehole, Tap and Well water, were collected so many times from different sampling points and locations. The parameters determined include pH, Temperature, Mean Electrical conductivity and Standard Deviation (SD). The results showed that, well water has the highest conductivity of 0.0065794 followed by Borehole with 0.003923168 and lastly, the Tap water which has 0.0017659, which means that well water sample conducts more electricity followed by Borehole and Tap water samples. This is as a result of so many impurities and other dissolved ionic solutes found within the well. The research explicitly informed that, well water and borehole have less quality in Nassarawa Local Government Area, as such it is not good for human consumption.

Article PDF
Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Copyright (c) 2025 Engineering Research journal

333 185