Abstract
This study examined the thermal assessment and thermal comfort of some selected high rise residential buildings in Ikoyi, Lagos, Nigeria. The field observations and questionnaire survey were used and the data was tabulated and analyzed descriptively which resulted in the total number of respondents being 293 residents. The results indicated that there were significant variations in how climate responsive design features, including building orientation, natural ventilation, daylighting, spatial organization, and incorporation of landscape were utilized. The towers of Infinity Tower, Osborne Tower, Riverside Apartment and Labana Luxury Apartment showed a positive thermal-responsive performance, and the towers of Cilonzes Height showed the lowest performance. Also results indicated a high reliance on mechanical cooling, 72.7% of residents being air conditioned. While most reported good thermal conditions, most comfort was obtained by use of active cooling devices, not passive design. The study concludes that in tropical high-rise residential buildings, the effective passive design strategies have a significant contribution to improve thermal comfort and sustainability.

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Copyright (c) 2026 African Journal of Environment and Sustainable Development